DICHANG T8 LED tube range

Commercial performance, configured for the project.

Three standard lengths with project-selected wattage and CCT, PF > 0.9, Flicker-Free commercial configuration and single-end input.

PF > 0.9Flicker-Free3000K–6500K5-year warranty
DICHANG commercial T8 LED tubes

Managed product catalogue

Current commercial product range.

Product specifications below are managed independently from the website theme. Publish, edit or add products in WordPress under DICHANG Products.

Product data

Technical comparison

Published series parameters from the current DICHANG T8 LED Product Handbook.

Parameter600 mm1200 mm1500 mm
Power options4-15W8-28W8-30W
Luminous efficacy150+ lm/W150+ lm/W150+ lm/W
Luminous flux600-2250 lm1200-4200 lm1200-4500 lm
Input voltageAC175-260VAC175-260VAC175-260V
DriverHigh-PF constant-current ICHigh-PF constant-current ICHigh-PF constant-current IC
Power factor>0.9>0.9>0.9
Flicker specificationFlicker-FreeFlicker-FreeFlicker-Free
CRI>80>80>80
Input typeSingle-end inputSingle-end inputSingle-end input
End capsFlame-retardant PCFlame-retardant PCFlame-retardant PC
CCT3000K-6500K3000K-6500K3000K-6500K
Warranty5 Years5 Years5 Years
PackagingPearl cotton sleeve + labelPearl cotton sleeve + labelPearl cotton sleeve + label
Outer carton30 pcs/carton30 pcs/carton30 pcs/carton

The handbook lists an AC175-260V driver input range for the three product series. Compliance documents may state the certified fixed-model rating separately.

Representative fixed-power test samples

Measured 6500K performance.

The measurements below are stored with each product and can be edited independently in WordPress.

600 mm Series

Product details →

9W FIXED MODEL

0.6M | SINGLE-END EMC

153.2 lm/WEfficacy
1,451.7 lmLuminous flux
Measured power
9.473 W
Measured CCT
6473 K
CRI Ra
81.9
PF / SDCM
0.9399 / 2.3

Test 0565 | 9 Aug 2026

Open test report →

15W FIXED MODEL

0.6M | SINGLE-END EMC

151.4 lm/WEfficacy
2,307.8 lmLuminous flux
Measured power
15.24 W
Measured CCT
6489 K
CRI Ra
82.3
PF / SDCM
0.9616 / 1.7

Test 0568 | 9 Aug 2026

Open test report →

1200 mm Series

Product details →

18W FIXED MODEL

1.2M | SINGLE-END EMC

151.6 lm/WEfficacy
2,739.2 lmLuminous flux
Measured power
18.07 W
Measured CCT
6486 K
CRI Ra
82.0
PF / SDCM
0.9720 / 1.8

Test 0566 | 9 Aug 2026

Open test report →

28W FIXED MODEL

1.2M | SINGLE-END EMC

154.5 lm/WEfficacy
4,465.9 lmLuminous flux
Measured power
28.91 W
Measured CCT
6506 K
CRI Ra
82.1
PF / SDCM
0.9734 / 2.2

Test 0569 | 9 Aug 2026

Open test report →

1500 mm Series

Product details →

24W FIXED MODEL

1.5M | SINGLE-END EMC

156.8 lm/WEfficacy
3,787.3 lmLuminous flux
Measured power
24.15 W
Measured CCT
6482 K
CRI Ra
83.0
PF / SDCM
0.9633 / 0.6

Test 0570 | 9 Aug 2026

Open test report →

30W FIXED MODEL

1.5M | SINGLE-END EMC

151.3 lm/WEfficacy
4,659.3 lmLuminous flux
Measured power
30.80 W
Measured CCT
6484 K
CRI Ra
82.1
PF / SDCM
0.9759 / 2.2

Test 0567 | 9 Aug 2026

Open test report →

Flexible project configuration

Fixed-power test samples, flexible project range.

Laboratory results shown on this site apply to the tested 6500K samples. Other wattage and CCT configurations are project-specific within the published series range.

Flicker-Free is an engineering and product specification in the current handbook and is not a measurement reported by the supplied spectrophotocolorimeter sample reports.

Product handbook Company and product handbook with technical parameters and representative test results. Open handbook PDF →
T8 installation guide Graphical replacement steps plus key G13, electrical and operating safety notes. Open installation guide → The bundled manual illustrates a 1200 mm / 18 W example. Confirm the selected product specification on the product page or formal quotation.

Production and protection

From finished tube to protected delivery.

Factory and quality-control images illustrate manufacturing and product handling context.

Illustrative underground car park application

Specification support

Tell us the space, not just the wattage.

Tube length, operating hours, desired CCT, fitting condition, quantity and delivery location all matter. DICHANG uses those inputs to confirm a formal project configuration and price.

Ready to specify the range?

Start with product series, quantity, preferred CCT and delivery postcode.

Request a formal quote