Compliance and verification

Documentation that supports responsible Australian supply.

DICHANG’s T8 range is supported by a Global-Mark Certificate of Conformity, a Responsible Supplier Declaration and an AS/NZS CISPR 15:2025 EMC test report.

Photometric laboratory with integrating spheres and lighting test equipment
01

Electrical safety certification

Certificate of Conformity GMA-528952-EA, issued by Global-Mark for six DICHANG double-capped LED lamp models.

02

Responsible Supplier declaration

DICHANG PTY LTD is identified as the Australian Responsible Supplier for the covered Level 3 equipment.

03

EMC test report

Report BC-107E-1278/26 records passing results for the applicable AS/NZS CISPR 15:2025 emission tests.

Primary documents

The evidence behind the compliance page.

Global-Mark

Certificate of Conformity

Certificate GMA-528952-EA. Issued 30 June 2026 and shown with an expiry date of 30 June 2031, subject to ongoing certification conditions.

Open certificate →
EESS

Responsible Supplier Declaration

Declaration for DICHANG PTY LTD covering the six T8 model numbers associated with the certificate.

Open declaration →
BCT

AS/NZS CISPR 15:2025 Test Report

EMC report issued 11 July 2026 for the DICHANG double-capped LED lamp range.

Open EMC report →

Certificate coverage

Six fixed-power models across three lengths.

LengthModelRatingClassification
600 mmT8-9W-G139 W220–240 V~, 50/60 Hz, IP20, Class II, Type A
600 mmT8-15W-G1315 W220–240 V~, 50/60 Hz, IP20, Class II, Type A
1200 mmT8-18W-G1318 W220–240 V~, 50/60 Hz, IP20, Class II, Type A
1200 mmT8-28W-G1328 W220–240 V~, 50/60 Hz, IP20, Class II, Type A
1500 mmT8-24W-G1324 W220–240 V~, 50/60 Hz, IP20, Class II, Type A
1500 mmT8-30W-G1330 W220–240 V~, 50/60 Hz, IP20, Class II, Type A
Project-selected wattage and CCT configurations are confirmed against the final quotation and project specification. Current project configurations are available with power factor above 0.9 and Flicker-Free commercial configuration.

EMC summary

Applicable emission tests recorded as Pass.

The report summary records passing results for disturbance voltage at the power supply interface, LLAS radiated disturbance and radiated disturbances using the CDN method.

  • 9 kHz–30 MHz disturbance voltage: Pass
  • 9 kHz–30 MHz LLAS radiated disturbance: Pass
  • 30 MHz–300 MHz radiated disturbances, CDN method: Pass
EMC test environment and measurement rig

Laboratory and quality context

Specialist environments for product review and verification.

Laboratory photographs illustrate testing and quality-control environments. Formal claims are based on the downloadable documents above.

Need compliance documents with a quotation?

Include the project type and requested model range so the relevant documents can be supplied together.

Request a project quote